MOQ: | one pcs |
Price: | 1000-100000USD/Negotiable |
Standard Packaging: | wooden case |
Delivery Period: | 7-15days |
Payment Method: | L/C,D/A,D/P,T/T |
Supply Capacity: | 100 pcs a month |
High Altitude and Low Pressure Simulation Test Chamber for Battery
I. Product Overview:
This test chamber is designed according to UL, EN, IEC, and other standard testing requirements. It can rapidly achieve the low-pressure storage state of the sample and automatically control the test cycle. The pressure changes within the chamber are monitored throughout the test, and the test is automatically terminated once the set parameters are met. The chamber simulates the storage conditions for batteries and battery packs at a pressure of 11.6 kPa or lower and an ambient temperature of (20±5)℃ for 6 hours. A battery is considered qualified if there is no leakage, no gas emission, no disintegration, no rupture, and no fire, and the open-circuit voltage of each tested battery or battery pack after the test is not less than 90% of its voltage before the simulation test.
II. Compliance Standards:
GB/T 18287, UL 2054, UN 38.3, UL 1642, IEC 61960, IEC 62133, and other relevant testing standards.
Specification
Impulse voltage | AC 1kv/1.2-50μs(maximum value)1min |
DC response time | ≤5μs |
Voltmeter | Measuring voltage: 0-100V; Display accuracy: F.S ± 0.5% RDG ± 1digit; |
Maximum short circuit current | 1000A or 2000A selectable |
Ammeter | Measuring current: 0-1000A/2000A; Display accuracy: F.S ± 0.5% RDG ± 1digit; |
temperature range | RT+10℃ ~ +130℃(adjustable) |
Temperature fluctuation | 0.5℃ |
Power Supply | AC 220V10% 50HZ |
MOQ: | one pcs |
Price: | 1000-100000USD/Negotiable |
Standard Packaging: | wooden case |
Delivery Period: | 7-15days |
Payment Method: | L/C,D/A,D/P,T/T |
Supply Capacity: | 100 pcs a month |
High Altitude and Low Pressure Simulation Test Chamber for Battery
I. Product Overview:
This test chamber is designed according to UL, EN, IEC, and other standard testing requirements. It can rapidly achieve the low-pressure storage state of the sample and automatically control the test cycle. The pressure changes within the chamber are monitored throughout the test, and the test is automatically terminated once the set parameters are met. The chamber simulates the storage conditions for batteries and battery packs at a pressure of 11.6 kPa or lower and an ambient temperature of (20±5)℃ for 6 hours. A battery is considered qualified if there is no leakage, no gas emission, no disintegration, no rupture, and no fire, and the open-circuit voltage of each tested battery or battery pack after the test is not less than 90% of its voltage before the simulation test.
II. Compliance Standards:
GB/T 18287, UL 2054, UN 38.3, UL 1642, IEC 61960, IEC 62133, and other relevant testing standards.
Specification
Impulse voltage | AC 1kv/1.2-50μs(maximum value)1min |
DC response time | ≤5μs |
Voltmeter | Measuring voltage: 0-100V; Display accuracy: F.S ± 0.5% RDG ± 1digit; |
Maximum short circuit current | 1000A or 2000A selectable |
Ammeter | Measuring current: 0-1000A/2000A; Display accuracy: F.S ± 0.5% RDG ± 1digit; |
temperature range | RT+10℃ ~ +130℃(adjustable) |
Temperature fluctuation | 0.5℃ |
Power Supply | AC 220V10% 50HZ |